1) Sheath of multicore cable not entering an enclosure a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 2) Absence of RCD protection for socket outlets used outdoor a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 3) Use of unsheathed flex for lighting pendants a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 4) Absence of earthing at socket outlet a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 5) An accessory is badly damaged a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 6) Utility water pipe used as the means of earthing a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 7) Absence of RCD for circuits in a bathroom a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 8) Live conductors have no insulation a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 9) A ‘borrowed neutral’, for example where a single circuit neutral is shared by 2 circuits a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 10) Exposed live part are accessible to touch a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 11) a fuse carrier or circuit-breaker is missing from a CU with no blanking plate in place a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 12) Absence of RCD protection for cables ≤ 50mm deep in a wall a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 13) Absence of main protective bonding a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 14) terminations or connections have no (or damaged) barriers or enclosures a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 15) Absence of a reliable earth connection to a recessed metallic back box a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 16) Installation not divided into an adequate number of circuits a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 17) CSA of main earthing conductor too small a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 18) Absence of ‘Safety Electrical Connection — Do Not Remove notice a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 19) Main protective bonding to gas, water or other service pipe inaccessible for inspection a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 20) Switch lines not identified as line conductors at terminations a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation
0%
EICR Codes
共有
共有
共有
Wlcconstruction
さんの投稿です
コンテンツの編集
印刷
埋め込み
もっと見る
割り当て
リーダーボード
もっと表示する
表示を少なくする
このリーダーボードは現在非公開です。公開するには
共有
をクリックしてください。
このリーダーボードは、リソースの所有者によって無効にされています。
このリーダーボードは、あなたのオプションがリソースオーナーと異なるため、無効になっています。
オプションを元に戻す
迷路の追跡
は自由形式のテンプレートです。リーダーボード用のスコアは生成されません。
ログインが必要です
表示スタイル
フォント
サブスクリプションが必要です
オプション
テンプレートを切り替える
すべてを表示
アクティビティを再生すると、より多くのフォーマットが表示されます。
オープン結果
リンクをコピー
QRコード
削除
自動保存:
を復元しますか?