1) Sheath of multicore cable not entering an enclosure a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 2) Absence of RCD protection for socket outlets used outdoor a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 3) Use of unsheathed flex for lighting pendants a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 4) Absence of earthing at socket outlet a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 5) An accessory is badly damaged a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 6) Utility water pipe used as the means of earthing a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 7) Absence of RCD for circuits in a bathroom a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 8) Live conductors have no insulation a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 9) A ‘borrowed neutral’, for example where a single circuit neutral is shared by 2 circuits a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 10) Exposed live part are accessible to touch a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 11) a fuse carrier or circuit-breaker is missing from a CU with no blanking plate in place a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 12) Absence of RCD protection for cables ≤ 50mm deep in a wall a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 13) Absence of main protective bonding a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 14) terminations or connections have no (or damaged) barriers or enclosures a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 15) Absence of a reliable earth connection to a recessed metallic back box a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 16) Installation not divided into an adequate number of circuits a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 17) CSA of main earthing conductor too small a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 18) Absence of ‘Safety Electrical Connection — Do Not Remove notice a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 19) Main protective bonding to gas, water or other service pipe inaccessible for inspection a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 20) Switch lines not identified as line conductors at terminations a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation
0%
EICR Codes
공유
공유
공유
만든이
Wlcconstruction
콘텐츠 편집
인쇄
퍼가기
더보기
할당
순위표
더 보기
접기
이 순위표는 현재 비공개입니다.
공유
를 클릭하여 공개할 수 있습니다.
자료 소유자가 이 순위표를 비활성화했습니다.
옵션이 자료 소유자와 다르기 때문에 이 순위표가 비활성화됩니다.
옵션 되돌리기
미로 찾기
(은)는 개방형 템플릿입니다. 순위표에 올라가는 점수를 산출하지 않습니다.
로그인이 필요합니다
비주얼 스타일
글꼴
구독 필요
옵션
템플릿 전환하기
모두 표시
액티비티를 플레이할 때 더 많은 포맷이 나타납니다.
결과 열기
링크 복사
QR 코드
삭제
자동 저장된
게임을 복구할까요?