Identify the device shown in the image., Autoclave (Moist heat sterilization)., What is the standard condition (Temperature, Time, and Pressure) for this device?, 121°C for 20-30 minutes at 15 psi., What is the mechanism of action for sterilization in this device?, Denaturation of proteins, Name two parts of the Autoclave and their functions based on the diagrams., Pressure Gauge: Indicates the pressure inside the autoclave. .Safety Valve (Exhaust): Stops pressure from exceeding the maximum; keeps pressure constant. , Identify the device shown, Hot Air Oven (Dry heat sterilization)., What are the standard conditions for this device?, 160-170°C for 1-2 hours., What is the mechanism of action for dry heat?, Oxidation, Give examples of materials that can be sterilized in this oven., Powders, oils, ointments, and glassware., Why can we NOT use this device for culture media?, Because it causes charring (burning)., What is the function of the "Air circulating fan" inside this oven?, Helps in uniform distribution of heat., Filtration is used for which type of liquids?, Aqueous liquids and heat-labile substances (substances destroyed by heat)., Identify the filter type, Membrane Filter., Identify the filter type, Depth Filter, identify the filter type, Sintered Glass Filter., identify the filter type , Chamberland Filter., What is the standard pore size for a membrane filter to achieve sterilization?, 0.22 micrometre or 0.45 micrometre., Which filter cannot be used for corrosive liquids?, Seitz filter and Membrane filter., Identify the "Chemical Indicator" shown in the image., Steri tape, How do you confirm successful sterilization using Steri tape?, By a color change (diagonal lines appear/darken after autoclaving)., What is the name of the microorganism used as a "Biological Indicator" for steam sterilization?, Spores of Bacillus stearothermophilus., Interpret the results of the biological indicator vial after incubation:, Spores are viable (not killed); objects are NOT sterile., Interpret the results of the biological indicator vial after incubation:, Spores were killed; objects ARE sterile., In the biological indicator vial, why must you "squeeze" the flexible vial after autoclaving?, To break the internal glass ampoule and release the nutrient medium onto the spore strip for incubation..
0%
Section 3
Kopīgot
Kopīgot
Kopīgot
autors:
Mariamalak677
Rediģēt saturu
Drukāt
Iegult
Vairāk
Uzdevumus
Līderu saraksts
Rādīt vairāk
Rādīt mazāk
Šī līderu grupa pašlaik ir privāta. Noklikšķiniet uz
Kopīgot
, lai to publiskotu.
Mācību līdzekļa īpašnieks ir atspējojis šo līderu grupu.
Šī līderu grupa ir atspējota, jo jūsu izmantotās iespējas atšķiras no mācību līdzekļa īpašnieka iespējām.
Atjaunot sākotnējās iespējas
Atmiņas kāršu spēle
ir atvērta veidne. Tā neģenerē rezultātus līderu grupai.
Nepieciešams pieteikties
Vizuālais stils
Fonts
Nepieciešams abonements
Iespējas
Pārslēgt veidni
Rādīt visus
Atskaņojot aktivitāti, tiks parādīti vairāki formāti.
)
Atvērtie rezultāti
Kopēt saiti
QR kods
Dzēst
Atjaunot automātiski saglabāto:
?