single mode - Used for long-distance transmissions, single mode fibers have a smaller core and support higher bandwidth with less signal attenuation., Multi mode - Suitable for shorter distances, multimode fibers have a larger core, which allows multiple light modes but can cause more signal dispersion and attenuation over longer distances., Category 5/6/7/8 - Using a lower category cable (e.g., Cat5) instead of a higher category (e.g., Cat6, Cat7, or Cat8) can limit data transfer speeds and lead to increased errors, Shielded twisted pair (STP) vs Unshielded twisted pair (UTP) - Using UTP cables in environments with high electromagnetic interference (EMI) instead of STP can result in signal degradation on and data corruption., Signal degradation - signal diminishes over distance or due to interference , crosstalk - specific type of signal degradation where a signal transmitted on one cable or channel interferes with a signal on another cable or channel., interference - disruption of signal transmission caused by electromagnetic signals from other electronic devices or cables., Attenuation - gradual loss of signal strength as it travels through a cable or medium., Improper termination - occurs when network cables are not correctly terminated with the appropriate connectors or techniques., Transmitter (tx)/receiver (rx) transposed - happens when the transmitter and receiver wires are incorrectly connected, causing communication failures., Increasing interface counters - Interface counters track various metrics related to network traffic and errors. Increasing counters indicate potential issues that need to be addressed to maintain optimal network performance, Cyclic redundancy check (CRC) - occur when there is a mismatch in the data checksum, indicating data corruption during transmission., Runts - packets that are smaller than the minimum allowed size (usually less than 64 bytes)., Giants - packets that exceed the maximum allowed size (usually greater than 1518 bytes for Ethernet frames)., Drops - occur when packets are discarded due to congestion, bu er overflow, or configuration issues.,
0%
5.2 Troubleshoot cabling/interface
Paylaş
Paylaş
Paylaş
Gprimal
tarafından
Comptia
N10-009
Network plus
İçeriği Düzenle
Yazdır
Yerleştir
Daha fazla
Ödevler
Skor Tablosu
Daha fazla göster
Daha az göster
Bu lider panosu şu anda gizlidir. Herkese açmak için
Paylaş
'a tıklayın.
Bu lider panosu kaynak sahibi tarafından devre dışı bırakıldı.
Seçenekleriniz kaynak sahibinden farklı olduğu için bu lider panosu devre dışı bırakıldı.
Seçenekleri Eski Haline Döndür
Eşleştir
açık uçlu bir şablondur. Bir lider panosu için skor oluşturmaz.
Giriş gereklidir
Görsel stil
Yazı tipleri
Abonelik gerekli
Seçenekler
Şablonu değiştir
Tümünü göster
Siz etkinliği oynarken daha fazla format görüntülenir.
Sonuçları aç
Bağlantıyı kopyala
QR kodu
Sil
Otomatik olarak kaydedilen geri yüklensin mi:
?