1) Sheath of multicore cable not entering an enclosure a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 2) Absence of RCD protection for socket outlets used outdoor a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 3) Use of unsheathed flex for lighting pendants a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 4) Absence of earthing at socket outlet a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 5) An accessory is badly damaged a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 6) Utility water pipe used as the means of earthing a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 7) Absence of RCD for circuits in a bathroom a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 8) Live conductors have no insulation a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 9) A ‘borrowed neutral’, for example where a single circuit neutral is shared by 2 circuits a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 10) Exposed live part are accessible to touch a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 11) a fuse carrier or circuit-breaker is missing from a CU with no blanking plate in place a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 12) Absence of RCD protection for cables ≤ 50mm deep in a wall a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 13) Absence of main protective bonding a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 14) terminations or connections have no (or damaged) barriers or enclosures a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 15) Absence of a reliable earth connection to a recessed metallic back box a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 16) Installation not divided into an adequate number of circuits a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 17) CSA of main earthing conductor too small a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 18) Absence of ‘Safety Electrical Connection — Do Not Remove notice a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 19) Main protective bonding to gas, water or other service pipe inaccessible for inspection a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 20) Switch lines not identified as line conductors at terminations a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation

لوحة الصدارة

النمط البصري

الخيارات

تبديل القالب

استعادة الحفظ التلقائي: ؟