1) Sheath of multicore cable not entering an enclosure a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 2) Absence of RCD protection for socket outlets used outdoor a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 3) Use of unsheathed flex for lighting pendants a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 4) Absence of earthing at socket outlet a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 5) An accessory is badly damaged a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 6) Utility water pipe used as the means of earthing a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 7) Absence of RCD for circuits in a bathroom a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 8) Live conductors have no insulation a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 9) A ‘borrowed neutral’, for example where a single circuit neutral is shared by 2 circuits a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 10) Exposed live part are accessible to touch a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 11) a fuse carrier or circuit-breaker is missing from a CU with no blanking plate in place a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 12) Absence of RCD protection for cables ≤ 50mm deep in a wall a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 13) Absence of main protective bonding a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 14) terminations or connections have no (or damaged) barriers or enclosures a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 15) Absence of a reliable earth connection to a recessed metallic back box a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 16) Installation not divided into an adequate number of circuits a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 17) CSA of main earthing conductor too small a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 18) Absence of ‘Safety Electrical Connection — Do Not Remove notice a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 19) Main protective bonding to gas, water or other service pipe inaccessible for inspection a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation 20) Switch lines not identified as line conductors at terminations a) Code 1Danger Present b) Code 2 Potentially Dangerous c) Code 3 Improvement Recommended d) Further Investigation
0%
EICR Codes Gameshow Quiz
Delen
Delen
Delen
door
Wlcconstruction
Inhoud Bewerken
Afdrukken
Embedden
Meer
Toewijzingen
Scorebord
Meer weergeven
Minder weergeven
Dit scoreboard is momenteel privé. Klik op
Delen
om het publiek te maken.
Dit scoreboard is uitgeschakeld door de eigenaar.
Dit scoreboard is uitgeschakeld omdat uw opties anders zijn dan die van de eigenaar.
Opties Herstellen
Gameshow quiz
is een open template. Het genereert geen scores voor een scoreboard.
Inloggen vereist
Visuele stijl
Lettertypen
Abonnement vereist
Opties
Template wisselen
Alles weergeven
Er zullen meer templates verschijnen terwijl je de activiteit gebruikt.
Open resultaten
Kopieer link
QR-code
Verwijderen
Automatisch opgeslagen activiteit "
" herstellen?