single mode - Used for long-distance transmissions, single mode fibers have a smaller core and support higher bandwidth with less signal attenuation., Multi mode - Suitable for shorter distances, multimode fibers have a larger core, which allows multiple light modes but can cause more signal dispersion and attenuation over longer distances., Category 5/6/7/8 - Using a lower category cable (e.g., Cat5) instead of a higher category (e.g., Cat6, Cat7, or Cat8) can limit data transfer speeds and lead to increased errors, Shielded twisted pair (STP) vs Unshielded twisted pair (UTP) - Using UTP cables in environments with high electromagnetic interference (EMI) instead of STP can result in signal degradation on and data corruption., Signal degradation - signal diminishes over distance or due to interference , crosstalk - specific type of signal degradation where a signal transmitted on one cable or channel interferes with a signal on another cable or channel., interference - disruption of signal transmission caused by electromagnetic signals from other electronic devices or cables., Attenuation - gradual loss of signal strength as it travels through a cable or medium., Improper termination - occurs when network cables are not correctly terminated with the appropriate connectors or techniques., Transmitter (tx)/receiver (rx) transposed - happens when the transmitter and receiver wires are incorrectly connected, causing communication failures., Increasing interface counters - Interface counters track various metrics related to network traffic and errors. Increasing counters indicate potential issues that need to be addressed to maintain optimal network performance, Cyclic redundancy check (CRC) - occur when there is a mismatch in the data checksum, indicating data corruption during transmission., Runts - packets that are smaller than the minimum allowed size (usually less than 64 bytes)., Giants - packets that exceed the maximum allowed size (usually greater than 1518 bytes for Ethernet frames)., Drops - occur when packets are discarded due to congestion, bu er overflow, or configuration issues.,
0%
5.2 Troubleshoot cabling/interface
Podeli
Podeli
Podeli
autor
Gprimal
Comptia
N10-009
Network plus
Uredi sadržaj
Odštampaj
Ugradi
Više
Zadatke
Tabela
Prikaži više
Prikaži manje
Ova tabela je trenutno privatna. Kliknite na
Podeli
da biste je objavili.
Pristup tabeli je onemogućio vlasnik sredstva.
Ova tabela je onemogućena pošto Vam se podešavanja razlikuju od podešavanja vlasnika sredstva.
Vrati podešavanja
Spoji
je otvoreni šablon. On ne generiše rezultate za tabelu rangiranja.
Prijava je obavezna
Vizuelni stil
Fontove
Potrebna je pretplata
Postavke
Promeni šablon
Prikaži sve
Više formata će se pojaviti tokom igranja aktivnosti.
Otvoreni rezultati
Kopiraj vezu
QR kôd
Izbriši
Vrati automatski sačuvano:
?