1) Where are the statutory requirements for the installation of drainage systems? a) BS 6700 b) BS EN 12056 c) Building Regulations d) WRAS 2) Which one of the following is a type of plastic gutter profile? a) Mansard b) Ogee c) Half channel d) Elson 3) The maximum recommended length of a discharge pipe from a bath connected to a primary ventilated stack is: a) 3 metres b) 4 metres c) 5 metres d) 6 metres 4) What is the main purpose of the item identified? a) Boss connection b) WC connection c) Access for roding d) Air inlet valve 5) What is recommended to stop crossflow in a soil stack opposite a WC? a) Boss strap b) No connections for 100mm c) Air admittance valve d) No connections for 200mm 6) What is the recommended termination, as per Building Regulations, for a soil stack inside a building? a) Open ended b) Cowl c) Domical cage d) Air admittance valve 7) According to Building Regulations, what is the permissible drop in pressure during a soundness test on a soil stack? a) 38mm b) 25mm c) 10mm d) Nil 8) If a discharge branch has a gradient of 18mm per metre and the branch is 3 metres in length, what would the vertical drop distance be? a) 54mm b) 18mm c) 36mm d) 72mm 9) Identify this type of stack system: a) Primary ventilated stack b) Secondary ventilated stack c) Ventilated discharge branch stack d) Stub stack 10) What is the main purpose of a rainwater system? a) Filter surface water prior to entry of the surface water drain b) Stop penetration of rainwater into the property c) Route all rainwater to the soakaway d) Stop foul smells at high level 11) When installing a cast iron soil stack, a ladder is used to gain access to some scaffolding. How many rungs of the ladder should be above the working area? a) 2 b) 3 c) 4 d) 9 12) What type of screws are recommended to be used when attaching facia brackets to the facia board? a) Stainless steel b) Galvanised c) Brass d) Chrome plated 13) What would be the best way to prevent a customer from using a sanitary appliance whilst work is being carried out on the soil stack? a) Write a letter to the customer b) Place warning notices on the appliances c) Isolate the electrics in the property d) Isolate the incoming cold water 14) If an air admittance valve is located within some boxing, what is required to allow the valve to operate effectively? a) Access from the loft area b) Additional ventilation in the boxing c) The boxing must be sealed d) Only one appliance can be discharged at any one time 15) What is the minimum sized waste that is allowed to be fitted to a washbasin? a) 32mm b) 40mm c) 50mm d) 100mm 16) What problem may occur if the waste pipe gradient from a washbasin is too steep? a) Compression b) Capillary action c) Self-siphonage d) Momentum 17) After a performance test, what is the minimum trap seal depth allowed? a) 10mm b) 15mm c) 25mm d) 50mm 18) If you realise that a customer’s WC is connected to the surface water drain, what should you do? a) Nothing b) Advise the customer never to use the WC c) Advise the customer that it requires connecting to the foul water drain d) Advise the customer that the WC pan needs to be changed 19) In the Victorian period, what was a common material used in guttering? a) Cast iron b) Plastic c) Asbestos d) Pressed steel 20) If foul water and sewage were to come into contact with a plumber’s skin, the plumber could contract: a) Hepatitis b) Malaria c) Yellow fever d) Giardiasis

Tabela

Vizuelni stil

Postavke

Promeni šablon

Vrati automatski sačuvano: ?